Regular peel force testing is crucial to control production process. Off-line operation mode allows users to make the test and get immediate result response trough three color display. Quality management can retrieve all measurements from device trough Ethernet connection for reporting or controlling the process. A total traceability of measurements from one hand.
Touch screen operation
Measurement setup and start trough touch screen.
Three colour screen signalizing machine state or measurement status:
- Green: normal operation / test passed OK
- Orange: setup
- Red: malfunction / test passed NOK
Setup menu provide settings as:
- Test parameters
- Measurement limits
- and many more…
Holding Lever
Holding lever can be lifted up to allow operator easy placing of carrier tape sample.
Height of the holding plate is adjusted to maximum pocket depth 25mm, other dimensions on request.
Cover Tape Holding Lever
Easy cover tape fixing with eccentric lever.
Moveable joint eliminates clamping irregularities.
Overload protection.
Calibration Wheel
Device is supplied internally pre-calibrated.
Regular calibration can be done with the calibration weight set.
Yearly recalibration according to ISO 17025 is available.
Software
Multifunctional software package with allow user to browse between stored data, set user rights, download measurement options and tape data as lot of other options.
Supports both Off-Line or On-Line mode
Peel test according | EN 60286-3:2007 |
Tape pitch | From 8mm to 200mm |
Max pocket depth | 40mm |
Measuring range | From 0N to 3N (other on request |
Resolution | 0,01N |
Measurement tolerance | +-(0,02 +2%)N |
Power supply | 230VAC, 50/60Hz, 2A |
Dimensions (L x D x H) | 400mm x 250mm x 170mm |
Weight | 3kg |